Read More

Aflatoxin M1 Rapid Test Strips

  • Aug 27, 2026   Anon

Aflatoxin M1 Rapid Test Strips (0.03ppb) different detection limit test is available based on request


Catalog No.: LSY-20038K6

1. Brief

This product is used for testing Aflatoxin M1 in raw milk and dairy products sample qualitatively. The whole test only needs 11 min, easy to operate with high sensitivity.

2. Packing:  96tests/box


3. Components

1) 12 tubes: each tube includes 8 test strips and 8 micro-wells red solid reagent.

2) Manual: 1 piece.

 

4. Application

Dairy products: fresh milk, pasteurized milk, pure cow/goat milk, whole milk powder (dissolve 1g of milk powder in 9ml of pure water and mix thoroughly)

 

5. Detection limit

Test name

Detection limit (μg/kg)

Aflatoxin M1

0.03


6. Date of manufacture and batch number: See bag and outer box for details.

 

7. Principle

The colloidal gold immuno-chromatography was used to detect the aflatoxins M1 residue in the samples. The binding of aflatoxins M1 to the specific monoclonal antibody labeled with colloidal gold inhibited the binding of the antibody to the conjugates of aflatoxins M1-BSA on the NC membrane Testing line, which resulted in the color depth variation of the testing line.

 

8. Testing equipment

Instruments: Micropipette, 1 incubator, 1 Reader (optional), timer.

Consumables: disposable tips

 

9. Operation procedures

1) Return the test strip and sample to room temperature before use.

2) Take out tube, open it and take out the required number of micro-wells and test strips, and mark them properly. Please use it as soon as possible within 1 hour. After taking out the reagent, please immediately cover the remaining micro-wells and strips lid to prevent the remaining reagent from getting damp.

3) Use a micropipette to pipette 200 µl of the sample into the micro-well, slowly aspirate 5 times until the mixture is uniform, and observe with the naked eye that there is no solid substance.

4) After incubating with a incubator (40±2) for 3 minutes, insert the test strip into the micro-well (with the MAX line end facing downwards, allowing it to be fully immersed in the solution).

4) After immersing the test strip in the micro-well for 8 minutes, interpret the results according to the schematic diagram. Please interpret the results within 1 minutes, otherwise interpretation will be invalid.

 

10. Test Result Interpretation

Color depth comparison of  T line and C line

Result judgment

Result analysis

T line > C line

Negative

Aflatoxins M1 residue is lower than detection limit 0.03μg/kg in sample

T line = C line

Weak Positive

Aflatoxins M1 residue is equal to detection limit =0.03μg/kgin sample

T line C line or T line is invisible

Positive

Aflatoxins M1 residue is higher than detection limit 0.03μg/kgin sample

C line is invisible

Invalid

The test dipstick is invalid, test again

AFM1 strip.png

11. Precautions

1) The test strip can be used only once at room temperature, do not use test strips out of expiry date.

2) Please seal the tube after taking out required test strips. If can not use all 8 micro-wells at once, cup the rest and put it back to tube and sealed.

3) Do not touch the white membrane surface in the middle of test strip, avoid sunlight and fan blowing directly.

4) Milk samples should be fully liquid without any agglomeration and deposition.

5) Use the test strips testing again for positive results.

6) Milk samples with high fat content may have slower chromatography speed. It is recommended to extend the reaction time for the second step by 1 minute.

7) The results is for reference only, for confirmation, please refer to the relevant national standard methods.

8) Please contact the supplier for any questions.

12. Safety performance and garbage disposal

This product's test strips and packaging are non-toxic and harmless. After use, they should be disposed of as dry waste.

13. Storage and expiry date

Storage:  Store at 2-8 in dark, sealed, dry place, no frozen.

Expiry date: 12 months

 

Shenzhen Lvshiyuan Biotechnology Co., Ltd 

D Building, National Biological Industrial Park of Marinelife, No.2 Binhai Road, Dapeng, Shenzhen, 518120 China

Tel. 86-755-28438788/86-18165709090    Fax 86-755-28938800

Email: info@lsybt.com  